Acceso | registro
产品中心
Inicio > Centro de productos > Vacuum circuit Breaker > Indoor Vacuum circuit Breaker > VBI-40.5 Floor Mounted Vacuum Circuit Breaker

VBI-40.5 Floor Mounted Vacuum Circuit Breaker

    VBI-40.5 Floor Mounted Vacuum Circuit Breaker

    VBI-40.5 Floor Mounted Vacuum Circuit Breaker The VBI-40.5 Floor Mounted Vacuum Circuit Breaker is a high-performance, medium-voltage switching device designed for reliable protection and control of electrical systems rated at 40.5kV. Utilizing advanced vacuum interrupter technology, it ensures efficient arc quenching, minimal maintenance, and a long operational lifespan. Ideal for power distribution networks, industrial plants, and substations, this breaker combines robust construction with user-friendly operation.
  • compartir:
  • Contáctanos Consulta en línea

VBI-40.5 Floor Mounted Vacuum Circuit Breaker

 

Product Introduction & User Manual

1. Product Overview

The VBI-40.5 Floor Mounted Vacuum Circuit Breaker is a high-performance, medium-voltage switching device designed for reliable protection and control of electrical systems rated at 40.5kV. Utilizing advanced vacuum interrupter technology, it ensures efficient arc quenching, minimal maintenance, and a long operational lifespan. Ideal for power distribution networks, industrial plants, and substations, this breaker combines robust construction with user-friendly operation.

 

2. Key Features

· Voltage Rating: 40.5kV (withstand 95kV lightning impulse).

· Current Rating: Up to 2500A continuous, 31.5kA short-circuit breaking capacity.

· Vacuum Interrupter: Hermetically sealed, maintenance-free, and environmentally friendly (no SFgas).

· Mechanism: Spring-operated or motor-driven储能 mechanism for quick closing/opening (<50ms).

· Safety: Integrated anti-slip design, mechanical/electrical interlocks, and grounding switches.

· Standards Compliance: Meets IEC 62271, GB/T 1984, and ANSI C37.04.

 

3. Installation Instructions

3.1 Pre-Installation Checks

· Verify intact packaging and no physical damage.

· Confirm rated parameters match system requirements.

· Ensure a level, vibration-free concrete foundation.

 

3.2 Mounting Steps

 

1.Secure the breaker to the floor using anchor bolts (M16 recommended).

2.Connect primary busbars with torque settings per manufacturer specs (e.g., 50Nm).

3.Wire secondary control cables to terminals (labeled Open/Close Coil,”“Auxiliary Contacts).

4.Ground the breaker chassis securely (接地电阻 ≤4Ω).

 

4. Operation Guide

4.1 Manual Operation

· Closing: Rotate the manual handle clockwise until a clickconfirms engagement.

· Opening: Press the red Tripbutton or pull the mechanical trip lever.

 

4.2 Electrical Operation

· Apply 220VDC/110VAC to the closing coil (momentary pulse) for remote control.

· Use the local/remote selector switch for mode切换.

 

4.3 Indicators & Alarms

· Green LED: Breaker closed.

· Red LED: Breaker open/tripped.

· Alarm Contacts: Trigger for SFpressure loss (if equipped) or spring未储能.

 

5. Maintenance & Troubleshooting

5.1 Routine Checks

· Inspect contacts every 5,000 operations (via viewport).

· Lubricate moving parts annually with high-temperature grease.

· Test insulation resistance (>1000MΩ @5kV).

 

5.2 Common Issues

· Failure to Close: Check control power, spring charge, or interlock conditions.

· Excessive Heating: Tighten connections; measure contact resistance (<50μΩ).

 

6. Safety Warnings

· De-energize the breaker before servicing.

· Only trained personnel should perform maintenance.

· Never operate with visible damage or abnormal noises.

 

7. Environmental & Disposal

· Dispose of vacuum interrupters as electronic waste (non-hazardous).

· Recycle metals and plastics per local regulations.

 

No.ItemUnitData
1Rated voltageKV40.5
21 min rated short-duration power frequency withstand voltageKV95
3Lighting impulse withstand voltageKV185
4Rated frequencyHz50/60
5Rated currentA630/1250/1600/2000/2500
6Rated short-circuit breaking currentKA20 | 25 | 31.5
7Rated short-circuit making current(peak value)KA50 | 63 | 80
8Rated short-time withstand currentKA20 | 25 | 31.5
9Rated peak withstand currentKA50 | 63 | 80
10Rated short-time withstand current durationS4
11Rated operating sequence
0-0.3s-CO-180s-CO
12Rated short-circuit current breaking timesTimes30
13Mechanical LifeTimes10000
14Contact opening distancemm20±2
15Contact overtravelmm6±1
16Average closing speedm/s0.6±0.2
17Average breaking speedm/s1.2±0.2
18Contact closing bounce timems≤3
19Contact Closing and Breaking Non-simultaneousms≤2
20Circuit resistance per phaseμΩ≤80
21Permissible accumulated wear thickness of dynamic and static contactmm3


MENSAJE EN LíNEA

Por favor, introduzca una dirección de correo electrónico válida
Código de verificación No puede estar vacío

PRODUCTOS RELACIONADOS

¡Sin resultados de búsqueda!

Contact Information

Contact Us

Company Address:

15-16F, Xianghe International Building, 

No.530 Kuntai Road, Kunshan City, 

Jiangsu Province, China.


Market Cooperation:

Manager Wu: 400-007-8608


Search

Este sitio web utiliza cookies para garantizar que obtenga la mejor experiencia en nuestro sitio web.

Aceptar rechazar